Skip to main navigation Skip to search Skip to main content

Three-dimensional catheter tip force sensing using multi-core fiber Bragg gratings

  • Omar Al-Ahmad*
  • , Mouloud Ourak
  • , Johan Vlekken
  • , Eric Lindner
  • , Emmanuel Vander Poorten
  • *Corresponding author for this work
  • KU Leuven
  • Fibre Bragg Grating Sensors Technologies GmbH
  • Robot Assisted Surgery (RAS)

Research output: Contribution to journal › Article › peer-review

Abstract

Awareness of catheter tip interaction forces is a crucial aspect during cardiac ablation procedures. The most important contact forces are the ones that originate between the catheter tip and the beating cardiac tissue. Clinical studies have shown that effective ablation occurs when contact forces are in the proximity of 0.2 N. Lower contact forces lead to ineffective ablation, while higher contact forces may result in complications such as cardiac perforation. Accurate and high resolution force sensing is therefore indispensable in such critical situations. Accordingly, this work presents the development of a unique and novel catheter tip force sensor utilizing a multi-core fiber with inscribed fiber Bragg gratings. A customizable helical compression spring is designed to serve as the flexural component relaying external forces to the multi-core fiber. The limited number of components, simple construction, and compact nature of the sensor makes it an appealing solution towards clinical translation. An elaborated approach is proposed for the design and dimensioning of the necessary sensor components. The approach also presents a unique method to decouple longitudinal and lateral force measurements. A force sensor prototype and a dedicated calibration setup are developed to experimentally validate the theoretical performance. Results show that the proposed force sensor exhibits 7.4 mN longitudinal resolution, 0.8 mN lateral resolution, 0.72 mN mean longitudinal error, 0.96 mN mean lateral error, a high repeatability, and excellent decoupling between longitudinal and lateral forces.

Original languageEnglish
Article number1154494
JournalFrontiers in Robotics and AI
Volume10
DOIs
Publication statusPublished - 2023
Externally publishedYes

Keywords

  • catheter ablation
  • fiber Bragg gratings
  • force sensor
  • miniaturized sensor
  • multi-core fiber

Fingerprint

Dive into the research topics of 'Three-dimensional catheter tip force sensing using multi-core fiber Bragg gratings'. Together they form a unique fingerprint.

Cite this