TY - JOUR
T1 - The Effectiveness of Wearable Devices Using Artificial Intelligence for Blood Glucose Level Forecasting or Prediction
T2 - Systematic Review
AU - Ahmed, Arfan
AU - Aziz, Sarah
AU - Abd-Alrazaq, Alaa
AU - Farooq, Faisal
AU - Househ, Mowafa
AU - Sheikh, Javaid
N1 - Publisher Copyright:
© Arfan Ahmed, Sarah Aziz, Alaa Abd-alrazaq, Faisal Farooq, Mowafa Househ, Javaid Sheikh. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 14.03.2023. This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included.
PY - 2023
Y1 - 2023
N2 - Background: In 2021 alone, diabetes mellitus, a metabolic disorder primarily characterized by abnormally high blood glucose (BG) levels, affected 537 million people globally, and over 6 million deaths were reported. The use of noninvasive technologies, such as wearable devices (WDs), to regulate and monitor BG in people with diabetes is a relatively new concept and yet in its infancy. Noninvasive WDs coupled with machine learning (ML) techniques have the potential to understand and conclude meaningful information from the gathered data and provide clinically meaningful advanced analytics for the purpose of forecasting or prediction. Objective: The purpose of this study is to provide a systematic review complete with a quality assessment looking at diabetes effectiveness of using artificial intelligence (AI) in WDs for forecasting or predicting BG levels. Methods: We searched 7 of the most popular bibliographic databases. Two reviewers performed study selection and data extraction independently before cross-checking the extracted data. A narrative approach was used to synthesize the data. Quality assessment was performed using an adapted version of the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Results: From the initial 3872 studies, the features from 12 studies were reported after filtering according to our predefined inclusion criteria. The reference standard in all studies overall (n=11, 92%) was classified as low, as all ground truths were easily replicable. Since the data input to AI technology was highly standardized and there was no effect of flow or time frame on the final output, both factors were categorized in a low-risk group (n=11, 92%). It was observed that classical ML approaches were deployed by half of the studies, the most popular being ensemble-boosted trees (random forest). The most common evaluation metric used was Clarke grid error (n=7, 58%), followed by root mean square error (n=5, 42%). The wide usage of photoplethysmogram and near-infrared sensors was observed on wrist-worn devices. Conclusions: This review has provided the most extensive work to date summarizing WDs that use ML for diabetic-related BG level forecasting or prediction. Although current studies are few, this study suggests that the general quality of the studies was considered high, as revealed by the QUADAS-2 assessment tool. Further validation is needed for commercially available devices, but we envisage that WDs in general have the potential to remove the need for invasive devices completely for glucose monitoring in the not-too-distant future.
AB - Background: In 2021 alone, diabetes mellitus, a metabolic disorder primarily characterized by abnormally high blood glucose (BG) levels, affected 537 million people globally, and over 6 million deaths were reported. The use of noninvasive technologies, such as wearable devices (WDs), to regulate and monitor BG in people with diabetes is a relatively new concept and yet in its infancy. Noninvasive WDs coupled with machine learning (ML) techniques have the potential to understand and conclude meaningful information from the gathered data and provide clinically meaningful advanced analytics for the purpose of forecasting or prediction. Objective: The purpose of this study is to provide a systematic review complete with a quality assessment looking at diabetes effectiveness of using artificial intelligence (AI) in WDs for forecasting or predicting BG levels. Methods: We searched 7 of the most popular bibliographic databases. Two reviewers performed study selection and data extraction independently before cross-checking the extracted data. A narrative approach was used to synthesize the data. Quality assessment was performed using an adapted version of the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Results: From the initial 3872 studies, the features from 12 studies were reported after filtering according to our predefined inclusion criteria. The reference standard in all studies overall (n=11, 92%) was classified as low, as all ground truths were easily replicable. Since the data input to AI technology was highly standardized and there was no effect of flow or time frame on the final output, both factors were categorized in a low-risk group (n=11, 92%). It was observed that classical ML approaches were deployed by half of the studies, the most popular being ensemble-boosted trees (random forest). The most common evaluation metric used was Clarke grid error (n=7, 58%), followed by root mean square error (n=5, 42%). The wide usage of photoplethysmogram and near-infrared sensors was observed on wrist-worn devices. Conclusions: This review has provided the most extensive work to date summarizing WDs that use ML for diabetic-related BG level forecasting or prediction. Although current studies are few, this study suggests that the general quality of the studies was considered high, as revealed by the QUADAS-2 assessment tool. Further validation is needed for commercially available devices, but we envisage that WDs in general have the potential to remove the need for invasive devices completely for glucose monitoring in the not-too-distant future.
KW - artificial intelligence
KW - blood glucose
KW - diabetes
KW - forecasting
KW - machine learning
KW - prediction
KW - wearable devices
UR - https://www.scopus.com/pages/publications/85150311282
U2 - 10.2196/40259
DO - 10.2196/40259
M3 - Review article
C2 - 36917147
AN - SCOPUS:85150311282
SN - 1439-4456
VL - 25
JO - Journal of Medical Internet Research
JF - Journal of Medical Internet Research
M1 - e40259
ER -