T1 - Test-retest reliability of the biodex system 4 isokinetic dynamometer for knee strength assessment in paediatric populations
AU - Tsiros, Margarita D.
AU - Grimshaw, Paul N.
AU - Shield, Anthony J.
AU - Buckley, Jonathan D.
PY - 2011/9
Y1 - 2011/9
N2 - Background: Isokinetic dynamometry is a widely used tool for measuring muscle strength in clinical intervention and rehabilitation as well as research in children. Objective: To assess the test-retest reliability of knee flexor/extensor strength using the Biodex Multi-Joint System 4 Isokinetic Dynamometer in children. Methods: Peak isometric knee extensor (KE) and peak isokinetic knee flexor (KF) torques of the dominant and nondominant limbs were assessed twice in 11 children aged 10 to 13 yrs, 7 to 10 days apart. Results: Peak torques were higher in the dominant limb (p ≤ 0.006). Peak isometric KE torque was 8.4% higher (SEM 2.5%) at the second testing session, but there was no interaction with the limb tested (p > 0.2). Peak isokinetic KE/KF torque ratios agreed well between tests and had intraclass correlation coefficients (ICCs) of 0.96. Conclusions: The dynamometer provides a reliable means of assessing knee strength in 10 to 13 year olds, with excellent testretest reliability for isokinetic KE/KF. A learning effect occurred when assessing isometric torque, indicating the importance of habituation for this measure.
AB - Background: Isokinetic dynamometry is a widely used tool for measuring muscle strength in clinical intervention and rehabilitation as well as research in children. Objective: To assess the test-retest reliability of knee flexor/extensor strength using the Biodex Multi-Joint System 4 Isokinetic Dynamometer in children. Methods: Peak isometric knee extensor (KE) and peak isokinetic knee flexor (KF) torques of the dominant and nondominant limbs were assessed twice in 11 children aged 10 to 13 yrs, 7 to 10 days apart. Results: Peak torques were higher in the dominant limb (p ≤ 0.006). Peak isometric KE torque was 8.4% higher (SEM 2.5%) at the second testing session, but there was no interaction with the limb tested (p > 0.2). Peak isokinetic KE/KF torque ratios agreed well between tests and had intraclass correlation coefficients (ICCs) of 0.96. Conclusions: The dynamometer provides a reliable means of assessing knee strength in 10 to 13 year olds, with excellent testretest reliability for isokinetic KE/KF. A learning effect occurred when assessing isometric torque, indicating the importance of habituation for this measure.
UR - https://www.scopus.com/pages/publications/80053116131
M3 - Article
C2 - 21927776
AN - SCOPUS:80053116131
SN - 0090-7421
VL - 40
SP - 115
EP - 119
JO - Journal of Allied Health
JF - Journal of Allied Health
IS - 3
ER -