Skip to main navigation Skip to search Skip to main content

Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer

  • M. Abbas
  • , M. Abbrescia
  • , H. Abdalla
  • , A. Abdelalim
  • , S. AbuZeid
  • , D. Aebi
  • , A. Agapitos
  • , A. Ahmad
  • , A. Ahmed
  • , W. Ahmed
  • , C. Aimè
  • , T. Akhter
  • , B. Alsufyani
  • , C. Aruta
  • , I. Asghar
  • , P. Aspell
  • , C. Avila
  • , J. Babbar
  • , Y. Ban
  • , R. Band
  • S. Bansal, L. Benussi, V. Bhatnagar, M. Bianco, S. Bianco, K. Black, L. Borgonovi, O. Bouhali, A. Braghieri, S. Braibant, S. Butalla, A. Cagnotta, S. Calzaferri, R. Campagnola, M. Caponero, J. Carlson, F. Cassese, N. Cavallo, S. S. Chauhan, B. Choudhary, S. Colafranceschi, A. Colaleo, A. Conde Garcia, A. Datta, A. De Iorio, G. De Lentdecker, D. Dell Olio, G. De Robertis, W. Dharmaratna, T. Elkafrawy, R. Erbacher, P. Everaerts, F. Fabozzi, F. Fallavollita, D. Fiorina, M. Franco, C. Galloni, P. Giacomelli, S. Gigli, J. Gilmore, M. Gola, A. Gutierrez, R. Hadjiiska, K. Hoepfner, M. Hohlmann, Y. Hong, H. Hoorani, T. Huang, P. Iaydjiev, A. Irshad, A. Iorio, F. Ivone, W. Jang, J. Jaramillo, Y. Jeong, Y. Jeng, E. Juska, B. Kailasapathy, T. Kamon, Y. Kang, P. Karchin, A. Kaur, H. Kaur, H. Keller, H. Kim, J. Kim, M. Kim, S. Kim, B. Ko, A. Kumar, S. Kumar, N. Lacalamita, J. S.H. Lee, A. Levin, Q. Li, F. Licciulli, L. Lista, K. Liyanage, F. Loddo, M. Luhach, M. Maggi, Y. Maghrbi, N. Majumdar, K. Malagalage, S. Martiradonna, C. McLean, J. Merlin, M. Misheva, G. Mocellin, L. Moureaux, A. Muhammad, S. Muhammad, S. Mukhopadhyay, M. Naimuddin, S. Nuzzo, R. Oliveira, P. Paolucci, I. C. Park, L. Passamonti, G. Passeggio, A. Peck, A. Pellecchia, N. Perera, L. Petre, D. Piccolo, D. Pierluigi, G. Raffone, F. Ramirez, A. Ranieri, G. Rashevski, D. Rathjens, B. Regnery, C. Rendon, C. Riccardi, B. Rossi, P. Rout, J. D. Ruiz, A. Russo, A. Safonov, A. K. Sahota, D. Saltzberg, G. Saviano, A. Shah, A. Sharma, R. Sharma, T. Sheokand, M. Shopova, F. Simone, J. Singh, U. Sonnadara, J. Sturdy, G. Sultanov, Z. Szillasi, D. Teague, D. Teyssier, M. Tytgat, I. Vai, N. Vanegas, R. Venditti, P. Verwilligen, W. Vetens, A. K. Virdi, P. Vitulo, A. Wajid, D. Wang, K. Wang, I. J. Watson, N. Wickramage, D. D.C. Wickramarathna, E. Yanes, S. Yang, U. Yang, Y. Yang, I. Yoon*, Z. You, I. Yu, S. Zaleski
*Corresponding author for this work
  • Karlsruhe Institute of Technology
  • National Institute for Nuclear Physics
  • Academy of Scientific Research and Technology
  • Cairo University
  • Helwan University
  • Zewail City of Science and Technology
  • Ain Shams University
  • Texas A&M University
  • Peking University
  • National Center for Physics
  • University of Delhi
  • Florida Institute of Technology
  • CERN
  • Universidad de los Andes Colombia
  • Panjab University
  • University of California at Davis
  • University of Wisconsin-Madison
  • University of Naples Federico II
  • University of California at Los Angeles
  • Université libre de Bruxelles
  • University of Ruhuna
  • Wayne State University
  • Bulgarian Academy of Sciences
  • RWTH Aachen University
  • Ghent University
  • University of Seoul
  • Universidad de Antioquia
  • Sungkyunkwan University
  • Hanyang University
  • University of Colombo
  • Seoul National University
  • American University of the Middle East
  • Saha Institute of Nuclear Physics
  • Institute for Nuclear Research
  • Vrije Universiteit Brussel
  • Sun Yat-Sen University

Research output: Contribution to journalArticlepeer-review

Abstract

The upgrade of the CMS detector for the high luminosity LHC (HL-LHC) will include gas electron multiplier (GEM) detectors in the end-cap muon spectrometer. Due to the limited supply of large area GEM detectors, the Korean CMS (KCMS) collaboration had formed a consortium with Mecaro Co., Ltd. to serve as a supplier of GEM foils with area of approximately 0.6 m2. The consortium has developed a double-mask etching technique for production of these large-sized GEM foils. This article describes the production, quality control, and quality assessment (QA/QC) procedures and the mass production status for the GEM foils. Validation procedures indicate that the structure of the Korean foils are in the designed range. Detectors employing the Korean foils satisfy the requirements of the HL-LHC in terms of the effective gain, response uniformity, rate capability, discharge probability, and hardness against discharges. No aging phenomena were observed with a charge collection of 82 mC cm−2. Mass production of KCMS GEM foils is currently in progress.

Original languageEnglish
Article number168723
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume1057
DOIs
Publication statusPublished - Dec 2023
Externally publishedYes

Keywords

  • CMS
  • Double-mask
  • GEM
  • High luminosity LHC

Fingerprint

Dive into the research topics of 'Production and validation of industrially produced large-sized GEM foils for the Phase-2 upgrade of the CMS muon spectrometer'. Together they form a unique fingerprint.

Cite this