Modified operating parameter-based iyer correlation for the coefficient of performance (cop) prediction of different fluid pairs in double-effect vapor absorption refrigeration (var) cycles

Muhammad Saad Khan, Sambhaji T. Kadam, Alexios Spyridon Kyriakides, Ibrahim Hassan, Athanasios I. Papadopoulos, Mohammad Azizur Rahman, Panos Seferlis

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Citations (Scopus)

Abstract

Vapor absorption refrigeration (VAR) is a sustainable alternative to the conventional vapor compression refrigeration (VCR) cycle, owing to its lower non-renewable energy requirements and potentially for exploitation of renewable energy sources. Traditionally, the coefficient of performance (COP) of the conventional single effect VAR cycle is considerably lower than VCR cycles. This provides room for improvement which can be attained through double effect VAR cycles that provide relatively higher performance. The COP of the dual effect VAR cycle is enhanced due to the waste/rejected heat energy utilization from the condenser or the absorber into a secondary generator. Models that correlate the COP of the double effect VAR cycle with operating parameters are not available in the open literature, with Iyer's correlation being the only exception. This work applies this COP correlation using literature data for double effect VAR that operate with a variety of refrigerant and absorbent pairs. A comprehensive Mean Absolute Percentage Error (MAPE) analysis is performed for more than 2028 data points of various fluid pairs. Results reveal that MAPE (86.6-839%) values appear to be quite high for the reported correlation. Furthermore, the model is optimized using the proposed data set, considerably reducing the MAPE up to 36.03%. The results also indicate that due to the lack of fluidspecific parameters, the application of this correlation may not support the development of new double effect VAR cycles. Therefore, it is crucial to establish a performance-based correlation that considers both operational parameters and fluid parameters to assess the performance of new and efficient dual effect VAR cycles.

Original languageEnglish
Title of host publicationFluid Applications and Systems; Fluid Measurement and Instrumentation
PublisherAmerican Society of Mechanical Engineers (ASME)
ISBN (Electronic)9780791885291
DOIs
Publication statusPublished - 2021
Externally publishedYes
EventASME 2021 Fluids Engineering Division Summer Meeting, FEDSM 2021 - Virtual, Online
Duration: 10 Aug 202112 Aug 2021

Publication series

NameAmerican Society of Mechanical Engineers, Fluids Engineering Division (Publication) FEDSM
Volume2
ISSN (Print)0888-8116

Conference

ConferenceASME 2021 Fluids Engineering Division Summer Meeting, FEDSM 2021
CityVirtual, Online
Period10/08/2112/08/21

Keywords

  • COP
  • Double effect VAR cycle
  • Error analysis
  • Performance-based correlations.

Fingerprint

Dive into the research topics of 'Modified operating parameter-based iyer correlation for the coefficient of performance (cop) prediction of different fluid pairs in double-effect vapor absorption refrigeration (var) cycles'. Together they form a unique fingerprint.

Cite this