N2 - Vision-Language Models (VLMs) show promise for automating medical image interpretation, yet their reliability for clinical deployment remains uncertain. This paper presents a comprehensive evaluation of five VLMs (Gemini 2.0 Flash, Gemini 3 Pro Preview, Gemini 3 Flash, MedGemma 27B, MedGemma 4B) on fetal ultrasound annotation across eight structured clinical questions. Using expert sonographer annotations as ground truth, we assess accuracy using macro-averaged F1 (multi-label questions), exact-match accuracy (categorical questions), and mean absolute error (MAE) for gestational age estimation. We introduce a four-level hallucination severity taxonomy (none/minor/major/critical) and quantify clinical safety via false-alarm and over-escalation rates. Our findings reveal critical safety concerns: all models achieve a 0% safe-prediction rate (95% CI 0–11% per model), with anatomical structure F1 of 0.18±0.05, a false-alarm rate of 85±7% on normality assessment, an over-escalation rate of 68±16% for clinical recommendations, and gestational-age MAE of 8.4±0.9 weeks. These results indicate that current VLMs are not yet suitable for autonomous clinical deployment and require close human oversight.
AB - Vision-Language Models (VLMs) show promise for automating medical image interpretation, yet their reliability for clinical deployment remains uncertain. This paper presents a comprehensive evaluation of five VLMs (Gemini 2.0 Flash, Gemini 3 Pro Preview, Gemini 3 Flash, MedGemma 27B, MedGemma 4B) on fetal ultrasound annotation across eight structured clinical questions. Using expert sonographer annotations as ground truth, we assess accuracy using macro-averaged F1 (multi-label questions), exact-match accuracy (categorical questions), and mean absolute error (MAE) for gestational age estimation. We introduce a four-level hallucination severity taxonomy (none/minor/major/critical) and quantify clinical safety via false-alarm and over-escalation rates. Our findings reveal critical safety concerns: all models achieve a 0% safe-prediction rate (95% CI 0–11% per model), with anatomical structure F1 of 0.18±0.05, a false-alarm rate of 85±7% on normality assessment, an over-escalation rate of 68±16% for clinical recommendations, and gestational-age MAE of 8.4±0.9 weeks. These results indicate that current VLMs are not yet suitable for autonomous clinical deployment and require close human oversight.
KW - Clinical Safety
KW - Fetal Ultrasound
KW - Hallucination Detection
KW - Medical AI Evaluation
KW - Vision-Language Models
UR - https://www.scopus.com/pages/publications/105054212646
U2 - 10.1007/978-3-032-39379-1_23
DO - 10.1007/978-3-032-39379-1_23
M3 - Conference contribution
AN - SCOPUS:105054212646
SN - 9783032393784
T3 - Lecture Notes in Computer Science
SP - 320
EP - 334
BT - Pattern Recognition. ICPR 2026 International Workshops, Proceedings
A2 - Sintorn, Ida-Maria
A2 - Pal, Umapada
A2 - Lu, Shijian
PB - Springer Science and Business Media Deutschland GmbH
Y2 - 17 August 2026 through 22 August 2026
ER -