Skip to main navigation Skip to search Skip to main content

AI-Driven Analysis of Cardiopulmonary Exercise Tests to Identify Gas Exchange and Ventilatory Thresholds

  • Daniel A. Keir*
  • , Andrea Zignoli
  • , Danilo Iannetta
  • , Felipe Mattioni Maturana
  • , Juan M. Murias
  • *Corresponding author for this work
  • Western University
  • Toronto General Hospital Research Institute
  • Lawson Health Research Institute
  • University of Trento
  • University of Brescia
  • University of Tübingen

Research output: Contribution to journalArticlepeer-review

Abstract

Background: A cardiopulmonary exercise test (CPET) provides the estimated lactate threshold (θLT) and respiratory compensation point (RCP) through visual identification of multivariate gas exchange and ventilatory profiles. Artificial intelligence tools, such as deep neural networks, can learn, replicate, and classify these patterns and potentially aid in θLT and RCP identification, removing the subjectivity of threshold detection. This study evaluated a set of deep learning models (Oxynet) pre-trained with more than 1200 CPET files and tested its performance against visual inspection of experts. Methods: Evaluation included three phases: In phase I, 50 simulated ventilatory and gas exchange CPET files were generated, mixed with 50 authentic files, presented sequentially and in randomized order to three independent evaluators, and judged to be real or fake. In phase II, a new set of 50 files were generated, θLT and RCP were identified by both Oxynet and the consensus of three experts, and these estimates were compared with known values. In phase III, a subset of 163 CPETs were used to fine-tune Oxynet, and its evaluation of 50 independent authentic ramp CPET files were compared with those of the three experts. Results: Experts correctly discriminated simulated from authentic data in 44% of cases (phase I). One-way ANOVA revealed no main effect of identified V˙O2 (known vs Oxynet vs human evaluators) for both θLT (p = 0.41) and RCP (p = 0.39) with ~ zero effect size for both θLT2 = 0.00) and RCP (ω2 = 0.00) (phase II). Using real ramp-incremental data (phase III), the fine-tuned Oxynet identified the V˙O2 at 1944 ± 401 and 2555 ± 602 mL min−1 for θLT and RCP, respectively. Expert evaluators identified these at 1900 ± 469 and 2581 ± 625 mL min−1 with mean between-method biases of 45 mL min−1 (p = 0.087) and − 26 mL min−1 (p = 0.118). Conclusions: Oxynet can be used as an accurate, reliable, and objective tool to identify or aid in the identification of exercise thresholds from gas exchange and ventilatory CPET data in healthy individuals.

Original languageEnglish
JournalSports Medicine
Early online dateMar 2026
DOIs
Publication statusPublished - 5 Mar 2026

Fingerprint

Dive into the research topics of 'AI-Driven Analysis of Cardiopulmonary Exercise Tests to Identify Gas Exchange and Ventilatory Thresholds'. Together they form a unique fingerprint.

Cite this