TY - GEN
T1 - A stabilizer based predictive control scheme for smart inverters in weak grid
AU - Umar, Muhammad Farooq
AU - Khan, Ahmad
AU - Shadmand, Mohammad B.
N1 - Publisher Copyright:
© 2020 IEEE.
PY - 2020/2/7
Y1 - 2020/2/7
N2 - This paper presents a self-stabilization mechanism based on finite-set model predictive control (FCS-MPC) framework for smart inverters operating in weak grid conditions. As weak grid's large parasitic impedance and low short-circuit-ratio (SCR) challenge the stable operation of grid-connected inverters. Specifically, the inverter may experience frequencies that might excite the LCL filter resonance phenomenon. The inverter stability collapses if this LCL resonance is triggered. To address this issue, a robust predictive controller is proposed that features a self-stabilization mechanism for smart inverters interacting with a weak grid. The proposed methodology utilizes the idea that in stiff grid conditions the grid current feedback (GCF) is stable and in weak grid conditions the inverter current feedback (ICF) is stable. Therefore, the proposed FCS-MPC toggles between GCF and ICF to achieve inherent LCL filter resonance damping. The toggling action between GCF and ICF is leveraged by comparing the moving RMS grid current with threshold current as a constrained in the proposed FCS-MPC cost function. The theoretical analyses are verified by several case studies for a single-phase grid-connected inverter. The analysis and results demonstrated that the proposed FCS-MPC operates well under weak, ultra-weak and stiff grid conditions.
AB - This paper presents a self-stabilization mechanism based on finite-set model predictive control (FCS-MPC) framework for smart inverters operating in weak grid conditions. As weak grid's large parasitic impedance and low short-circuit-ratio (SCR) challenge the stable operation of grid-connected inverters. Specifically, the inverter may experience frequencies that might excite the LCL filter resonance phenomenon. The inverter stability collapses if this LCL resonance is triggered. To address this issue, a robust predictive controller is proposed that features a self-stabilization mechanism for smart inverters interacting with a weak grid. The proposed methodology utilizes the idea that in stiff grid conditions the grid current feedback (GCF) is stable and in weak grid conditions the inverter current feedback (ICF) is stable. Therefore, the proposed FCS-MPC toggles between GCF and ICF to achieve inherent LCL filter resonance damping. The toggling action between GCF and ICF is leveraged by comparing the moving RMS grid current with threshold current as a constrained in the proposed FCS-MPC cost function. The theoretical analyses are verified by several case studies for a single-phase grid-connected inverter. The analysis and results demonstrated that the proposed FCS-MPC operates well under weak, ultra-weak and stiff grid conditions.
KW - Model predictive control
KW - Self-healing control
KW - Self-stabilization
KW - Smart inverter
KW - Weak grid
UR - https://www.scopus.com/pages/publications/85083080733
U2 - 10.1109/TPEC48276.2020.9042561
DO - 10.1109/TPEC48276.2020.9042561
M3 - Conference contribution
AN - SCOPUS:85083080733
T3 - 2020 IEEE Texas Power and Energy Conference, TPEC 2020
BT - 2020 IEEE Texas Power and Energy Conference, TPEC 2020
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2020 IEEE Texas Power and Energy Conference, TPEC 2020
Y2 - 6 February 2020 through 7 February 2020
ER -