N2 - AI data centers experience rapid fluctuations in power demand due to the heterogeneity of computational tasks that they have to support. For example, the power profile of inference and training of large language models (LLMs) is quite distinct and big divergences can result in the instability of the electric grid. In this paper we propose, to the best of our knowledge, the first physics-informed DLinear time-series model that can accurately forecast power utilization of an AI data center 5-80 minutes (short-term forecasting) into the future. The physics, based on a multi-node lumped thermal resistance-capacitance (RC) network consistent with Newton's law of cooling, is captured using newly derived time-dependent ordinary differential equations (ODE) that separately models and interlinks power consumption with the GPU compute and memory utilization and temperature. The resulting model, that we refer to as PI-DLinear, trained and evaluated on a real AI data center dataset, is not only more accurate than the state-of-the-art (SOTA) models tested, but the forecast profile respects the underlying physics under power throttling and load transient events. Relative to the SOTA transformer-based and non-transformer-based models, improvements in forecasting accuracy (averaged across all look-back and prediction windows) range from 0.782% - 39.08% for MSE, 0.993% - 51.82% for MAE, and 0.370% - 22.28% for RMSE.
AB - AI data centers experience rapid fluctuations in power demand due to the heterogeneity of computational tasks that they have to support. For example, the power profile of inference and training of large language models (LLMs) is quite distinct and big divergences can result in the instability of the electric grid. In this paper we propose, to the best of our knowledge, the first physics-informed DLinear time-series model that can accurately forecast power utilization of an AI data center 5-80 minutes (short-term forecasting) into the future. The physics, based on a multi-node lumped thermal resistance-capacitance (RC) network consistent with Newton's law of cooling, is captured using newly derived time-dependent ordinary differential equations (ODE) that separately models and interlinks power consumption with the GPU compute and memory utilization and temperature. The resulting model, that we refer to as PI-DLinear, trained and evaluated on a real AI data center dataset, is not only more accurate than the state-of-the-art (SOTA) models tested, but the forecast profile respects the underlying physics under power throttling and load transient events. Relative to the SOTA transformer-based and non-transformer-based models, improvements in forecasting accuracy (averaged across all look-back and prediction windows) range from 0.782% - 39.08% for MSE, 0.993% - 51.82% for MAE, and 0.370% - 22.28% for RMSE.
KW - ai data centers
KW - dlinear
KW - gpu power forecasting
KW - physics-informed machine learning
KW - power throttling
KW - thermal rc modeling
UR - https://www.scopus.com/pages/publications/105051063114
U2 - 10.1145/3770855.3818033
DO - 10.1145/3770855.3818033
M3 - Conference contribution
AN - SCOPUS:105051063114
T3 - Proceedings of the ACM SIGKDD International Conference on Knowledge Discovery and Data Mining
SP - 4115
EP - 4126
BT - KDD 2026 - Proceedings of the 32nd ACM SIGKDD Conference on Knowledge Discovery and Data Mining V.2
PB - Association for Computing Machinery
T2 - 32nd ACM SIGKDD Conference on Knowledge Discovery and Data Mining V.1, KDD 2026
Y2 - 9 August 2026 through 13 August 2026
ER -